iec60870_5_101 21.5.13

There is a newer version of this package available.
See the version list below for details.
dotnet add package iec60870_5_101 --version 21.5.13                
NuGet\Install-Package iec60870_5_101 -Version 21.5.13                
This command is intended to be used within the Package Manager Console in Visual Studio, as it uses the NuGet module's version of Install-Package.
<PackageReference Include="iec60870_5_101" Version="21.5.13" />                
For projects that support PackageReference, copy this XML node into the project file to reference the package.
paket add iec60870_5_101 --version 21.5.13                
#r "nuget: iec60870_5_101, 21.5.13"                
#r directive can be used in F# Interactive and Polyglot Notebooks. Copy this into the interactive tool or source code of the script to reference the package.
// Install iec60870_5_101 as a Cake Addin
#addin nuget:?package=iec60870_5_101&version=21.5.13

// Install iec60870_5_101 as a Cake Tool
#tool nuget:?package=iec60870_5_101&version=21.5.13                

IEC 60870-5-101 Protocol

RTU Server Simulator, Master Client Simulator, Windows and Linux POSIX ARM, IEC101 Source Code in C, C++, C# .NET Programming

Support both balanced and unbalanced mode.

Make your RTU, protocol converter, Gateway, HMI, Data concentrator compatible with iec 101.

Download Evaluation Kit - IEC 101 Development Bundle

In the Development Bundle, We included IEC 101 Protocol Server Client Simulator, Windows and Linux SDK, C# projects, Doxygen documentation and Raspberry Pi, BeagleBone Demo library.

IEC 60870-5 part 101 Windows C C++ C# .NET Programming

IEC 60870-5-101 Demo Win DLL includes simple (Server & Client C programs, c# .net )example using a Command window and command line inputs.

The source code will allow you to quickly compile your own examples with the features of your existing development environment to work with our IEC 60870-5-101 DLL..IEC 101 Windows SDK contains Win DLL (precompiled library), Static link lib, Demo IEC101 Server & Client programs, Visual Studio Demo console project files, Doxygen .

We used Visual studio compiler to create the dll, sample test projects.

This evaluation package allows you to:

Access product manual(API documentation)(pdf, Doxygen html)

Browse the IEC 60870-5-101 library API documentation

Study the source code of the IEC 60870-5-101 examples provided

Modify and compile the IEC 60870-5-101 examples

Create your own IEC 60870-5-101 programs and test with leading test tools

You can use the source code of the application examples and modify them according to your needs.

IEC 60870-5-101 Source Code Windows C C++ C# .net Linux Arm POSIX C C++

The most complete implementation of IEC 101 protocol stack including File transfer (Monitor and Control Direction), Directory Commnads, Supports all type of Monitoring, command , parameter ASDUs.

Low memory footprint, easy start on any hardware platform, can operate with or without an operating system, delivered as a source code,

high configurability allows to use required features only, royalty-free licensing.

Salient Features

  • Written in ANSI-Standard C Source Code, under a strict corporate coding standard, and supports C++, C#

  • Transparent licensing scheme - No hidden costs, No deferred payments.

  • High performance, robust and scalable architecture

  • Provides a simple method for systems Integrators and OEMs to utilize standard tools to implement their systems

  • Our stacks are fully compliant with "POSIX" and tested in ubuntu, feroda, Debian, QNX, Linux Embedded OS and Various Cross compiler tool chains.

  • Our all protocol stack supports "POSIX compliant operating system"

  • Context-based event-driven model

  • Support both balanced and unbalanced mode

  • Multiple Server and Client Simulation

  • In a Single Server(link) simulate Multiple Stations (Common Address / Station Address)

  • Supports Background Scan, Cyclic Data Transmission, Double Transmission, Redundancy and File transfer.

  • Communication with redundant control systems and interruption-free switch over between redundant systems

  • Supports "Select-Before-Operate" and "Direct-Execute" command execution modes

  • Source Code Library allows a fast and cost efficient implementation

  • APIs are designed to be very easy to use and flexible

Knowledge Base - Interoperability

IEC 60870-5-101 Protocol Server Interoperability

IEC 60870-5-101 protocol Client Interoperability

Licensing

Source Code License model:

In this License model, We deliver complete source code of the protocol implementation according to the customer specified operating system(Windows, Linux, QNX...).

Customer may embed the library into unlimited copies of Multiple end-use products for worldwide manufacturing, branding and distribution. Original equipment manufacturers choose this model. They usually have multiple products in their pipeline.

Compiled Library License model:

In this License model, We deliver Dynamic/ Static compiled library (dll / lib) of the protocol implementation according to the customer specified operating system(Windows, Linux, QNX...).

Customer may embed the library into unlimited copies of Multiple end-use products for worldwide manufacturing, branding and distribution. Original equipment manufacturers choose this model. They usually have multiple products in their pipeline.

Simulator License model:

Annual subscription Based license:

An Annual License allows the customer to use the licensed software for one year, download updates and request technical support. At the end of the year the customer must renew their term license to continue using the software. In this License model, FreyrSCADA deliver Simulator Installer for Windows Operating System. The Customer can use the software company wide. Customer can install the software in many systems. There is no restriction like Hardware key (Dongle) and software key.

Unlimited year license:

A Perpetual License allows the customer to purchase a license to use the software forever. The Perpetual License also comes with an annual renewal fee that enables the customer to update the software to the latest version. In this License model, FreyrSCADA deliver Simulator Installer for Windows Operating System. The Customer can use the software company wide. Customer can install the software in many systems. There is no restriction like Hardware key (Dongle) and software key. For Unlimited year license, after a year, you will have the option to renew the Maintenance Plan to continue receiving technical support and upgrades. The renewal price after a year is 10% of the product list price at the time of renewal (optional). Without renew the AMC also the software works. But for technical support and upgrades, the customer has an option for AMC.

facebook

linkedin

youtube

twitter

pinterest

tumblr

blog

telegram

instagram

Download Evaluation Kit - IEC 101 Protocol Development Bundle

In the Development Bundle, We included IEC 60870-5 part 101 Protocol Server Client Simulator, Windows and Linux SDK, C# projects, Doxygen documentation and Raspberry Pi, BeagleBone Demo library.

Product Compatible and additional computed target framework versions.
.NET net5.0 was computed.  net5.0-windows was computed.  net6.0 was computed.  net6.0-android was computed.  net6.0-ios was computed.  net6.0-maccatalyst was computed.  net6.0-macos was computed.  net6.0-tvos was computed.  net6.0-windows was computed.  net7.0 was computed.  net7.0-android was computed.  net7.0-ios was computed.  net7.0-maccatalyst was computed.  net7.0-macos was computed.  net7.0-tvos was computed.  net7.0-windows was computed.  net8.0 was computed.  net8.0-android was computed.  net8.0-browser was computed.  net8.0-ios was computed.  net8.0-maccatalyst was computed.  net8.0-macos was computed.  net8.0-tvos was computed.  net8.0-windows was computed. 
.NET Core netcoreapp2.0 was computed.  netcoreapp2.1 was computed.  netcoreapp2.2 was computed.  netcoreapp3.0 was computed.  netcoreapp3.1 was computed. 
.NET Standard netstandard2.0 is compatible.  netstandard2.1 was computed. 
.NET Framework net461 was computed.  net462 was computed.  net463 was computed.  net47 was computed.  net471 was computed.  net472 was computed.  net48 was computed.  net481 was computed. 
MonoAndroid monoandroid was computed. 
MonoMac monomac was computed. 
MonoTouch monotouch was computed. 
Tizen tizen40 was computed.  tizen60 was computed. 
Xamarin.iOS xamarinios was computed. 
Xamarin.Mac xamarinmac was computed. 
Xamarin.TVOS xamarintvos was computed. 
Xamarin.WatchOS xamarinwatchos was computed. 
Compatible target framework(s)
Included target framework(s) (in package)
Learn more about Target Frameworks and .NET Standard.
  • .NETStandard 2.0

    • No dependencies.

NuGet packages

This package is not used by any NuGet packages.

GitHub repositories

This package is not used by any popular GitHub repositories.

Immp : Place "iec101win32d.dll" from "packages\iec60870_5_101.21.0x.00x\runtime\iec101win32d.dll" folder to your application output directory.
This package includes x86 binaries. You must specify the target platform in your IDE (i.e. you cannot use "AnyCPU / x64").
Both iec 101 server and client - file transfer (Monitoring and control direction) implemented.
All types of ASDU - Monitoring and control, Parameter typeids implemented and tested.
Technical support mail to support@freyrscada.com

iec101 server test program:
https://www.freyrscada.com/nuget/iec60870-5-101/iec101servertest.cs

iec101 server test program:
https://www.freyrscada.com/nuget/iec60870-5-101/iec101clienttest.cs