Pepperdash.Essentials.Plugins.Dsp.Biamp.Tesira 4.6.0

There is a newer version of this package available.
See the version list below for details.
dotnet add package Pepperdash.Essentials.Plugins.Dsp.Biamp.Tesira --version 4.6.0
                    
NuGet\Install-Package Pepperdash.Essentials.Plugins.Dsp.Biamp.Tesira -Version 4.6.0
                    
This command is intended to be used within the Package Manager Console in Visual Studio, as it uses the NuGet module's version of Install-Package.
<PackageReference Include="Pepperdash.Essentials.Plugins.Dsp.Biamp.Tesira" Version="4.6.0" />
                    
For projects that support PackageReference, copy this XML node into the project file to reference the package.
<PackageVersion Include="Pepperdash.Essentials.Plugins.Dsp.Biamp.Tesira" Version="4.6.0" />
                    
Directory.Packages.props
<PackageReference Include="Pepperdash.Essentials.Plugins.Dsp.Biamp.Tesira" />
                    
Project file
For projects that support Central Package Management (CPM), copy this XML node into the solution Directory.Packages.props file to version the package.
paket add Pepperdash.Essentials.Plugins.Dsp.Biamp.Tesira --version 4.6.0
                    
#r "nuget: Pepperdash.Essentials.Plugins.Dsp.Biamp.Tesira, 4.6.0"
                    
#r directive can be used in F# Interactive and Polyglot Notebooks. Copy this into the interactive tool or source code of the script to reference the package.
#:package Pepperdash.Essentials.Plugins.Dsp.Biamp.Tesira@4.6.0
                    
#:package directive can be used in C# file-based apps starting in .NET 10 preview 4. Copy this into a .cs file before any lines of code to reference the package.
#addin nuget:?package=Pepperdash.Essentials.Plugins.Dsp.Biamp.Tesira&version=4.6.0
                    
Install as a Cake Addin
#tool nuget:?package=Pepperdash.Essentials.Plugins.Dsp.Biamp.Tesira&version=4.6.0
                    
Install as a Cake Tool

3Series Tested 4Series-Tested

Tesira DSP Essentials Plugin (c) 2023

  1. INVALID TAGS BREAK THIS RELEASE
  2. Do not update Biamp FW independent of Crestron Software and Essentials

Biamp FW v4.7.2 requires Essentials v1.15.5, or newer

Biamp FW v.4.7.2 includes a change of "deprecated SSH ciphers" which eliminates the ability to connect over SSH using Essentials v1.15.4 and prior. Essentials v1.15.5 is compiled with the latest Crestron libraries, which are rleied upon for the SSH connection and resolves the issue.

License

Provided under MIT license

Overview

The Tesira plugin provides device control over the Biamp Tesira family of DSPs with regards to the most commonly used and requested attriute and control types.

Compatibility

This plugin has been tested with both Crestron 3-Series and 4-Series processors. It implements all available essentials interfaces relevant to a device of this type. This includes but is not limited to AudioCodecBase, IHasDspPresets, IBasicVolumeWithFeedback, IRoutingWithFeedback and IDeviceInfoProvider. Documentation for which controls implement each interface will be documented in each relevant controls section. Additionally, every component implements IKeyed and all devices are added to the DeviceManager unpon instantiation.

Upgrading from v3.x to v4

v4 runs on Essentials v3 (net8, 4-Series). v3.x (latest v3.8.2) is the Essentials v2 line. Most changes are fixes that make documented behaviour work. Check the items below against an existing system before upgrading.

Behaviour changes

Change Who is affected What to do
Meters are opt-in. A meter streams only while its subscribe join is high, or after Subscribe() is called on the meter device. v3.x subscribed every meter at startup. Programs that read meter levels (bridge level join or IMeterFeedback) without raising the meter's subscribe join Raise the subscribe join (Legacy d3501 + offset; Standalone d1) while the meter is shown, or call Subscribe(). Without a SIMPL bridge, set "subscribeOnStart": true on the meter. For level-threshold feedback, prefer a logic meter in the design
Raw level (dB text) moved from serial 300 to serial 400 on the Legacy map, so it no longer overwrites fader labels at bridgeIndex 100+ (#151). It is also on the Standalone map at serial 2. Programs reading s301+ for raw level Move to s401 + offset
Room combiners link bridgeIndex 1–66 only on the Legacy map. Higher indexes would overlap the router joins at 2601 and are logged and not linked. Configs with a room combiner bridgeIndex above 66 Renumber the combiner, or bridge it standalone
Subscription watchdog checks every 30 s (was every 2 minutes): its sentinels, plus 2 components in rotation. A +OK reply (the DSP had dropped subscriptions, for example after a design push) restores every subscription at once, without a reconnect. Components that can never subscribe (missing tag, bad attribute or index) are quarantined and logged once. Everyone; no action needed Optional: set watchdogSentinels to one component per partition. See Subscription watchdog
Commands are dropped while the Tesira is disconnected, with one log line per outage. When it reconnects, subscriptions report the DSP's actual state. Commands sent during an outage (a route, a level) are not replayed. Programs that relied on queued commands reaching the DSP after a reconnect Re-send after IsOnline goes high if that matters
Command queue: capacity 10,000 (was 2,000). It never blocks when full: it drops, with one warning per episode. Subscriptions and the plugin's own reads wait behind user commands, and writes keep their order. Nobody None

Joins and features that now work

These were documented in v3.x but didn't work. Programs that worked around them may see a change.

Area Now
Crosspoint On/Off joins Set the crosspoint. They sent no value before, and the DSP rejected them
Meter subscribe join Subscribes on high and unsubscribes on low. Before, only the unsubscribe worked
Preset recall by number (analog) Recalls the preset. Before, it never matched
Router (routerControlBlocks) Routes and reports every output: new Legacy joins at a/s 2601 + ((bridgeIndex − 1) × 64) + (output − 1), standalone a(joinStart + N − 1). The existing switcher join routes the first output. Before, no route was sent and feedback was dropped
Room combiner Subscribes to levelOut; group and the level limits read the right room
Crosspoint Off feedback and labels; meter offsets per bridgeIndex Linked on both bridge maps

New, opt-in

Feature Config
Save presets from the bridge (hold a preset join) with a 2 s Preset Saved pulse presetHoldTimeMs (default 0: off)
Logic Selector blocks as switchers logicSelectorControlBlocks
Watchdog tuning watchdogIntervalSecs (30), watchdogPatrolSize (2), watchdogSentinels
Periodic re-read of level limits levelRangePollIntervalSecs (0: off)
Fault monitoring (active fault list, count, severity) faultPollIntervalSecs (0: off), the FaultPollingEnable join, or SetFaultPolling (see Fault monitoring)

Feature Notes

Version 2.0.0+ now offers developers the opportunity to individually bridge each control rather than the entire DSP object. This should lead to more flexibility in development. In documentation below, all references to the original object type will be referred to as Legacy, while new object data will be referred to as Standalone

When utilizing a standalone object within a Eisc bridge, it is addressed utilizing first the name of the base device, followed by a pair of two hyphens, then the key of the component.

For a parent device with a key of dsp-1 and a component with the key of Fader01, the Standalone component key is dsp-1--Fader01.

The only exception to this rule is for the Base Standalone object, which has a key suffix of DeviceInfo

"type": "eiscApiAdvanced"

Subscription watchdog

The Tesira drops subscriptions without closing the session when a design is pushed or a partition restarts, often on blocks the push didn't touch. The plugin checks for this the way Biamp's own control modules do:

  • Every watchdogIntervalSecs (default 30), it re-subscribes the sentinels plus the next watchdogPatrolSize (default 2) components in rotation, so a check costs a few commands whatever the design size.
  • -ERR ALREADY_SUBSCRIBED means the subscription is still there. +OK means the DSP had dropped it, so every subscription is restored at once, without clearing the command queue or reconnecting.
  • A check whose subscribe can never succeed (missing instance tag, bad attribute or index, attribute that can't be subscribed) quarantines that component: it is logged once and not checked again until the next session.
  • No reply to a check still drops and re-opens the session, as before.
  • Subscriptions (startup, restores, checks) wait behind control commands in the plugin's command queue, so a restore burst never delays a button press.

Set watchdogSentinels to one component per partition: a push drops a partition's subscriptions together, so a sentinel in each one catches every push within one check. Without it, the first subscribed component is the sentinel and other partitions are caught when the patrol reaches them.

"watchdogIntervalSecs": 30,
"watchdogPatrolSize": 2,
"watchdogSentinels": [ "RmaRoom", "RmbRoom" ]

Fault monitoring

The plugin can report the Tesira's active faults, the same information Biamp's software and device management show: for example INDICATOR_MAJOR_IN_DEVICE / "one or more Dante flows inactive". It's off by default. The Tesira can't subscribe to faults, so when it's on, the plugin polls DEVICE get activeFaultList. Polls wait behind control commands in the queue and are skipped while the DSP is offline.

Ways to turn it on:

How Example Lasts
Config (the default at startup) "faultPollIntervalSecs": 60 in the DSP's properties. 0 or missing means off; 1-9 is raised to 10, and more than 86400 (1 day) is lowered to 86400 Always
Bridge join FaultPollingEnable (d11) Rising edge: on, at the config interval or 60 s. Falling edge: off Until the program restarts. The join never changes the config
Console devjson {"deviceKey":"dsp-1","methodName":"SetFaultPolling","params":[60]}. Use 0 to turn it off Until the program restarts. To keep it, set faultPollIntervalSecs in the config

The enable join acts only on a change. A SIMPL program that leaves it low doesn't turn off monitoring that the config turned on, including the low state the EISC sends when it comes online. devjson {"deviceKey":"dsp-1","methodName":"PollFaults"} (or a pulse on d13) polls once.

SIMPL restarts. The join follows the SIMPL program's state. If a SIMPL program turned polling on with the join and then restarts, it comes back with the join low, and that falling edge turns polling off. To keep polling on across a SIMPL restart, either:

  • raise the join again after startup, for example from a value the program saves and reads back from its own config. The rising edge turns polling back on and polls at once. Until that first reply arrives, the fault joins read as no faults, so if the program alarms on a fault clearing, have it ignore them until it finishes loading; or
  • set faultPollIntervalSecs in the Essentials config instead. Config-enabled polling never turns off on a SIMPL restart, and the plugin re-sends the current values when the EISC reconnects.

The joins are on the device join map (both the Legacy and the Standalone DeviceInfo object): see DeviceInfo. From code, use FaultMonitor on the DSP device: its feedbacks, Current (the parsed list) and the FaultsChanged event. A fault appearing, changing or clearing is also logged.

Installation

This plugin is provided as a published nuget package for your convenience.

Place the *.cplz file in the /users/programxx/plugins folder, and restart your program.


Controls and Configs

DeviceInfo

This object is built by default with a Biamp Tesira DSP and provides a method to send hardware-specific data across the bridge to SIMPL

This data is only accessible by linking the device to the bridge. The component key is always DeviceInfo - therefore when a Biamp Tesira DSP with the key dsp-1 is instantiated, a DeviceInfo component with the key of dsp-1--DeviceInfo will be added to the DeviceManager and will be accessible to any Essentials Bridge.

This device will also allow a direct passthru connection to the device if necessary and a method by which to trigger control resubscription.

If you do not choose to bridge a Standalone object, limited data is available on the Legacy object.

This control implements Essentials interfaces IDeviceInfoProvider and IKeyed

Digitals
Legacy Join Standalone Join Type (RW) Description
1 1 R Device Online
N/A 1 W Resubscribe Controls
11 11 RW Fault monitoring enable: rising edge on, falling edge off. Feedback: polling active
12 12 R Has fault
13 13 W Poll faults now
Analogs
Legacy Join Standalone Join Type (RW) Description
11 11 R Active fault count
12 12 R Fault severity: 0 none, 1 minor, 2 major, 3 critical
Serials
Legacy Join Standalone Join Type (RW) Description
N/A 1 R Device Name
N/A 2 RW Command Passthrough
N/A 3 R Serial Number
N/A 4 R Firmware Version
N/A 5 R Hostname
N/A 6 R IP Address
N/A 7 R MAC Address
11 11 R Fault ID: the most severe indicator, e.g. INDICATOR_MAJOR_IN_DEVICE
12 12 R Fault name, e.g. "Major Fault in Device"
13 13 R Active faults' names, comma-separated

The fault joins report only while fault monitoring is on.

Config Notes

This configuration matches a standard essentials device configuration at the base level, with only the type being different. This may have the type tesira, tesiraforte, tesiraserver, tesiradsp, or tesira-dsp.

{    
    "key": "TesiraDsp-1",
    "name": "TesiraDspTesting",
    "type": "tesiraDsp",
    "group": "dsp",
    "properties": {
        "control": {
            "endOfLineString": "\n",
            "deviceReadyResponsePattern": "",
            "method": "ssh",
            "tcpSshProperties": {
                "address": "10.11.50.191",
                "port": 22,
                "autoReconnect": true,
                "AutoReconnectIntervalMs": 10000,
                "username": "default",
                "password": "default",
                "disableSshEcho": true
            }
        }
    }
}

The disableSshEcho property is valid in Essentials 2.


Level / Mute

Controls objects with the attribute type of "level" or "mute" and subscribes to them as necessary.

This component only reports the level of the audio signal relative the the adjustable range

Within the Legacy object, this Join map represents a control that is part of an array of controls. Each join number = Join Map Number + fader bridgeIndex as defined by the config.

Within the Standalone object, this join map represents a single control as defined by the key in the bridge.

This Control implements Essentials interfaces IKeyed and IBasicVolumeWithFeedback

Digitals
Legacy Join Standalone Join Type (RW) Description
200 6 R Channel Visible
400 5 RW Mute Toggle
600 3 RW Mute On
800 4 RW Mute Off
1000 1 W Volume Up
1200 2 W Volume Down
Analogs
Legacy Join Standalone Join Type (RW) Description
200 1 RW Volume Level
400 2 R Icon (0 - Level, 1 - Mic)
600 3 R ControlType (0 Mute/Level, 1 LevelOnly, 2 MuteOnly)
800 4 R Permissions (Pass From Config)
Serials
Legacy Join Standalone Join Type (RW) Description
200 1 R Control Label (Pass From Config)
400 2 R Raw Level in dB (e.g., "-12 dB", "-50 dB")
Config Example

All Level/Mute configs must be part of a dictionary called faderControlBlocks.

"faderControlBlocks": {
    "LevelControl01": {
        "enabled": true,
        "isMic": false,
        "hasLevel": true,
        "hasMute": true,
        "index1" : 1,
        "index2" : 0,
        "label": "Room",
        "levelInstanceTag": "ROOMVOL",
        "muteInstanceTag": "ROOMVOL",
        "unmuteOnVolChange" : true,
        "incrementAmount" : "2.0",
        "permissions" : 0,
        "bridgeIndex" : 1
    }
}
Config Notes

enabled - enables the control to be subscribed and controlled. label - Passed directly across the eisc as the Label value. isMic - drives the icon feedback. hasLevel - in conjunction with hasMute, sets the ControlType. hasMute - in conjunction with hasStatus, sets the ControlType. index1 - Index 1 of the control point. index2 - Index 2 of the control point. levelInstanceTag - Instance tag of the level control. muteInstanceTag - Instance tag of the mute control. unmuteOnVolChange - if true, will unmute a muted control when the level increases. incrementAmount - the value in decimals by which a mute increment or decrement command will manipulate the level. permissions - Passed directly across the eisc as the Permissions value. bridgeIndex - The index of the control on a Legacy object

In the provided example config object, given a base object key of dsp-1, this control would have a standalone key of dsp-1--LevelControl01.


Switcher

Version 2.5.0 added the ability to configure SourceSelectors and Routers as different objects. It is recommended to use this mechanism in new projects.

Controls objects with the attribute type of sourceSelection and subscribes to them as necessary; input is not subscribed to.

Within the Legacy object, this Join map represents a control that is part of an array of controls. Each join number = Join Map Number + fader bridgeIndex as defined by the config.

Within the Standalone object, this join map represents a single control as defined by the key in the bridge.

This control implements Essentials interfaces IKeyed and IRoutingWithFeedback

Digitals
Legacy Join Standalone Join Type (RW) Description
150 1 W Poll
Analogs
Legacy Join Standalone Join Type (RW) Description
150 1 RW Source Selection
Serials
Legacy Join Standalone Join Type (RW) Description
150 1 R Control Label (Pass From Config)
N/A 2 R Source List XSIG (If Configured) or Routed Source
Config Example

All sourceSelector and router configs must be part of a dictionary called switcherControlBlocks. Router configs require that the "type" be set to "router"

"switcherControlBlocks" : {
    "SwitcherControl01" : {
        "enabled" : true,
        "label" : "switcher01",
        "index1" : 1
        "switcherInstanceTag" : "SourceSelector1",
        "type": "router",
        "bridgeIndex" : 1,
        "showRoutedStringFeedback": true,
        "pollIntervalMs" : 90000,
        "switcherInputs" : {
            "1" : {"label": "Input1" },
            "2" : {"label": "Input2" },
        },
        "switcherOutputs" : {
            "1" : { "label": "Output1" },
            "2" : { "label": "Output2" },
        }
    }
}
Config Notes

enabled - enables the control to be subscribed and controlled. label - Passed directly across the eisc as the Label value. index1 - Index 1 of the control point. type - Valid Types are sourceSelector or router switcherInstanceTag - Instance tag of the sourceSelection control bridgeIndex - The index of the control on a Legacy object switcherInputs - This is a dictionary of labels for inputs of the switcher. The keys must be integers. switcherOutputs - This is a dictionary of labels for outputs of the switcher. This is earmarked for future usage. The keys must be integers.

In the provided example config object, given a base object key of dsp-1, this control would have a standalone key of dsp-1--SwitcherControl01.


Router

Controls a Router block's input attribute, one route per output: output N can be set to any input M, and M = 0 clears it. Each output listed in routerOutputs is subscribed, so its feedback follows changes made anywhere (presets, Tesira software, other control systems). After every route the plugin reads that output back, because the DSP can merge changes made within one publish interval.

Within the Legacy object, each router has two kinds of joins:

  • The switcher slot (join 150 + offset, where offset = ((bridgeIndex − 1) × 2) + 1) carries the router's first output (the lowest number in routerOutputs), its label and a poll.
  • Per-output joins: output N of the router with bridgeIndex B is join 2601 + ((B − 1) × 64) + (N − 1). Each router holds up to 64 outputs, so bridgeIndex 1 uses 2601–2664, bridgeIndex 2 uses 2665–2728, and so on up to bridgeIndex 7 (2985–3048); higher bridgeIndex routers are logged and not linked (use the standalone bridge). The block sits between the room combiners and the dialers, within an EISC's 4000 joins.

Within the Standalone object, output N is analog joinStart + N − 1 (route) and serial joinStart + 100 + N − 1 (routed label), up to 64 outputs. Output 1 shares the old Source Selection join.

This control implements Essentials interfaces IKeyed and IRoutingWithFeedback

Digitals
Legacy Join Standalone Join Type (RW) Description
150 1 W Poll every output
Analogs
Legacy Join Standalone Join Type (RW) Description
150 1 RW First output: input to route (0 clears) and routed-input feedback
2601 + ((B − 1) × 64) + (N − 1) 1 + (N − 1) RW Output N: input to route (0 clears) and routed-input feedback
Serials
Legacy Join Standalone Join Type (RW) Description
150 1 R Control Label (Pass From Config)
N/A 2 R Source List XSIG (If Configured) or Routed Source
2601 + ((B − 1) × 64) + (N − 1) 101 + (N − 1) R Output N: label of the routed input
Config Example

All router configs must be part of a dictionary called routerControlBlocks.

{
    "routerControlBlocks" : {
        "RouterControl01" : {
            "enabled" : true,
            "label" : "switcher01",
            "routerInstanceTag" : "Router1",
            "bridgeIndex" : 1,
            "showRoutedStringFeedback": true,
            "routerInputs" : {
                "1" : {"label": "Input1" },
                "2" : {"label": "Input2" }
            },
            "routerOutputs" : {
                "1" : {"label": "Output1" },
                "2" : {"label": "Output2" }
            }
        }
    }
}
Config Notes

enabled - enables the control to be subscribed and controlled. label - Passed directly across the eisc as the Label value. index1 - With the legacy routerOutput only: that output's Tesira number (default: the next number after routerOutputs). routerInstanceTag - Instance tag of the router block bridgeIndex - The index of the control on a Legacy object (counts from 1) routerInputs - Labels for the router's inputs. The keys must be integers (Tesira input numbers). Only these inputs, and 0 (clear), can be routed. routerOutputs - Labels for the router's outputs. The keys must be integers (Tesira output numbers, from 1). Each one is subscribed, routable and bridged. routerOutput - Legacy single output (label only; its number is index1). It becomes an ordinary output alongside routerOutputs; prefer routerOutputs.

In the provided example config object, given a base object key of dsp-1, this control would have a standalone key of dsp-1--RouterControl01.


SourceSelector

Controls and subscribes to objects with the attribute type of sourceSelector.

Within the Legacy object, this Join map represents a control that is part of an array of controls. Each join number = Join Map Number + fader bridgeIndex as defined by the config.

Within the Standalone object, this join map represents a single control as defined by the key in the bridge.

This control implements Essentials interfaces IKeyed and IRoutingWithFeedback

Digitals
Legacy Join Standalone Join Type (RW) Description
150 1 W Poll
Analogs
Legacy Join Standalone Join Type (RW) Description
150 1 RW Source Selection
Serials
Legacy Join Standalone Join Type (RW) Description
150 1 R Control Label (Pass From Config)
N/A 2 R Source List XSIG (If Configured) or Routed Source
Config Example

All sourceSelector and router configs must be part of a dictionary called routerControlBlocks.

{
    "sourceSelectorControlBlocks" : {
        "sourceSelectorControl01" : {
            "enabled" : true,
            "label" : "sourceSelector01",
            "index1" : 1,
            "sourceSelectorInstanceTag" : "SourceSelector1",
            "bridgeIndex" : 1,
            "showRoutedStringFeedback": true,
            "pollIntervalMs" : 90000,
            "sourceSelectorInputs" : {
                "1" : {"label": "Input1" },
                "2" : {"label": "Input2" },
            }
        }
    }
}
Config Notes

enabled - enables the control to be subscribed and controlled. label - Passed directly across the eisc as the Label value. index1 - Index of the output number on the sourceSelector that you wish to control. sourceSelectorInstanceTag - Instance tag of the sourceSelection control bridgeIndex - The index of the control on a Legacy object sourceSelectorInputs - This is a dictionary of labels for inputs of the source selector block. The keys must be integers.

In the provided example config object, given a base object key of dsp-1, this control would have a standalone key of dsp-1--sourceSelectorControl01.


LogicSelector

Controls a Tesira Logic Selector block as a switcher. A Logic Selector has interlocked boolean channels: selecting one turns the others off, and selecting none turns the active one off. It behaves exactly like a SourceSelector: the same interfaces (IKeyed, IRoutingWithFeedback), the same Legacy and Standalone joins, and the same routing and feedback. Selection 0 means no channel.

Logic selectors share the DSP's switcher joins with source selectors, so give each a bridgeIndex that doesn't clash with a source selector's.

The plugin subscribes once per block, to the states attribute, which the Tesira publishes as one line for all channels ([false true false false]). It selects a channel with set state <channel> true.

Config Example

All logic selector configs must be part of a dictionary called logicSelectorControlBlocks.

{
    "logicSelectorControlBlocks" : {
        "logicSelector01" : {
            "enabled" : true,
            "label" : "Logic Selector 1",
            "logicSelectorInstanceTag" : "LogicSelector1",
            "bridgeIndex" : 3,
            "logicSelectorInputs" : {
                "1" : {"label": "Channel 1" },
                "2" : {"label": "Channel 2" },
                "3" : {"label": "Channel 3" },
                "4" : {"label": "Channel 4" }
            }
        }
    }
}
Config Notes

logicSelectorInstanceTag - instance tag of the Logic Selector block (sourceSelectorInstanceTag also works). logicSelectorInputs - labels for the block's channels; the keys must be channel numbers starting at 1 (sourceSelectorInputs also works). A selected channel without a label shows as "Input n". All other settings are as for a SourceSelector.


State

Controls objects with the attribute type of "state" and subscribes to them as necessary.

Within the Legacy object, this Join map represents a control that is part of an array of controls. Each join number = Join Map Number + (bridgeIndex − 1); bridgeIndex counts from 1, and a state with bridgeIndex 0 is logged and not linked.

Within the Standalone object, this join map represents a single control as defined by the key in the bridge.

This control implements Essentials interface IKeyed

Digitals
Legacy Join Standalone Join Type (RW) Description
1300 1 RW State Toggle
1450 2 RW State On
1600 3 RW State Off
Analogs

None

Serials
Legacy Join Standalone Join Type (RW) Description
1300 1 R Control Label (Pass From Config)
Config Example

All state configs must be part of a dictionary called stateControlBlocks.

{
    "stateControlBlocks" : {
        "StateControl1" : {
            "enabled" : true,
            "label" : "State01",
            "stateInstanceTag" : "LogicState1",
            "subscriptionInstanceTag" : "LogicMeter1",
            "index" : 1,
            "bridgeIndex" : 1
        }
    }
}

In the provided example config object, given a base object key of dsp-1, this control would have a standalone key of dsp-1--StateControl1.

Config Notes

enabled - enables the control to be subscribed and controlled. label - Passed directly across the eisc as the Label value. index - Index of the control point. stateInstanceTag - Instance tag of the state control subscriptionInstanceTag - (Optional) Instance tag of the meter control for subscribing to feedback. If null or empty, will attempt to subscribe to stateInstanceTag bridgeIndex - The index of the control on a Legacy object


Presets

If you intend to ONLY do direct preset calling by string, this object is NOT required to recall presets. This activity is provided by the base level device object for the Tesira DSP. It is also provided by the Standalone object Presets. This config object is required regardless of control object if preset control iby index is required.

This control implements Essentials interfaces IHasDspPresetSave (which extends IDspPresets) and IKeyed

By default, a preset's digital join recalls the preset on press. To save presets from the bridge, set presetHoldTimeMs on the DSP (see Config Notes). Then a short press recalls the preset on release, and holding the join for presetHoldTimeMs saves the DSP's current state to that preset. When the DSP confirms the save, the Preset Saved join pulses high for 2 seconds. A failed save (for example, -ERR PRESET_NOT_FOUND) is logged and does not pulse.

Digitals
Legacy Join Standalone Join Type (RW) Description
100 1 W Select Preset By Index (with presetHoldTimeMs: press recalls, hold saves)
N/A 1 R Preset is Available By Index
100 101 R Preset Saved By Index: pulses high for 2 seconds when a save is confirmed
Analogs

None

Serials
Legacy Join Join Type (RW) Description
100 1 R Preset Name by Index
100 1 W Recall Preset By Name
Config Example

All preset configs must be part of a dictionary called presets.

{
    "presetHoldTimeMs" : 3000,
    "presets" : {
        "SomeUniqueKey": {
            "label" : "Default",
            "presetName" : "Default Levels",
            "presetId" : 1101,
            "presetIndex" : 1
        }
    }
}

In the provided example config object, given a base object key of dsp-1, this control would have a standalone key of dsp-1--Presets.

Config Notes

label - Passed directly across the eisc as the Label value. presetName - the actual name of the preset as defined in biamp software presetID - the ID of the preset as defined in biamp software presetIndex - the index of the preset for the digital press recall presetHoldTimeMs - (optional, on the DSP, not per preset) milliseconds a preset join must be held to save that preset. 0 (the default) disables saving from the bridge, and the join recalls on press.

If a presetName is defined, you don't need a presetId and vice versa. One or the other will be fine. If you are utilizing the "select preset by name" methodology, no presets need be defined in config.


Dialer

VoIP Controls are tested

POTS Controls are added, but as of yet untested.

DTMF is automatically managed based on current hook state.

Within the Legacy object, this Join map represents a control that is part of an array of controls. Each join number = Join Map Number + (1 + (50 * (n- 1))), where n is the index of the dialer as defined by bridgeIndex.

For example, Incoming Call for Line 1 would be at join 3101, while the incoming call for Line 2 would be at join 3151.

Within the Standalone object, this join map represents a single control as defined by the key in the bridge.

This control implements Essentials interfaces AudioCodecBase and IKeyed

Digitals
Legacy Join Standalone Join Type (RW) Description
3100 1 R Incoming Call
3106 2 W Answer
3107 3 W End Call
3110 4 W Keypad 0
3111 5 W Keypad 1
3112 6 W Keypad 2
3113 7 W Keypad 3
3114 8 W Keypad 4
3115 9 W Keypad 5
3116 10 W Keypad 6
3117 11 W Keypad 7
3118 12 W Keypad 8
3119 13 W Keypad 9
3120 14 W Keypad *
3121 15 W Keypad #
3122 16 W Keypad Clear
3123 17 W Keypad Backspace
3124 18 RW Dial
3125 19 RW Auto Answer On
3126 20 RW Auto Answer Off
3127 21 RW Auto Answer Toggle
3129 22 RW On Hook
3130 23 RW Off Hook
3132 24 RW Do Not Disturb Toggle
3133 25 RW Do Not Disturb On
3134 26 RW Do Not Disturb Off
Analogs
Legacy Join Standalone Join Type (RW) Description
3100 1 R CallState Value
Serials
Legacy Join Standalone Join Type (RW) Description
3100 1 RW Dial String
3101 2 RW Dialer Label
3102 3 RW Last Number Dialed
3104 4 R Caller ID Number
3105 5 R Caller ID Name
Config Example

All dialer configs must be part of a dictionary called dialerControlBlocks.

{
    "dialerControlBlocks" : {
        "Dialer1" : {
            "enabled" : true,
            "label" : "Dialer 01",
            "isVoip" : true,
            "dialerInstanceTag" : "Dialer1",
            "controlStatusInstanceTag" : "VoIPControlStatus1",
            "index" : 1,
            "callAppearance" : 1,
            "clearOnHangup" : true,
            "appendDtmf" : false,
            "bridgeIndex" : 1
        }
    }
}

In the provided example config object, given a base object key of dsp-1, this control would have a standalone key of dsp-1--Dialer1.

Config Notes

enabled - enables the control to be subscribed and controlled. label - Passed directly across the eisc as the Label value. index - Index of the line you wish to manage. dialerInstanceTag - Instance tag of the dialer control controlStatusInstanceTag - Instance tag of the controlStatus control isVoip - sets the device type to VoIP for internal configuration. callAppearance - the index of the call appearance you wish to contorl in a VoIP line. clearOnHangup - if true will clear the Dial String whenever the line goes on hook. appendDtmf - if true will append DTMF digit presses to Dial String bridgeIndex - The index of the control on a Legacy object


Meter

Enables metering on the sepecified meter.
Using this is a bad idea, please avoid unless specifically requested.

Meters are opt-in: a meter streams only while something has asked for it. Raise the meter's subscribe join (or call Subscribe() on the meter device) to start it, and lower the join (or call UnSubscribe()) to stop it. A standalone program without a SIMPL bridge can set "subscribeOnStart": true on the meter instead, so it streams from session start; lowering the join or calling UnSubscribe() still stops it. A meter that was asked for is subscribed again after a reconnect, design push or resubscribe; one that wasn't stays off. Before v4, every meter was subscribed when the session started, whether or not anything used it. For level-threshold feedback, prefer a logic meter in the design, which publishes only when its state changes.

Within the Legacy object this Join map represents a control that is part of an array of controls. Each join number = Join Map Number + (bridgeIndex − 1); bridgeIndex counts from 1, and a meter with bridgeIndex 0 is logged and not linked.

Within the Standalone object, this join map represents a single control as defined by the key in the bridge.

This control implements Essentials interface IKeyed

Digitals
Legacy Join Standalone Join Type (RW) Description
3501 1 RW Meter subscribe: high subscribes, low unsubscribes (one join per meter); feedback: subscribed
Analogs
Legacy Join Standalone Join Type (RW) Description
3501 1 R Meter Feedback
Serials
Legacy Join Standalone Join Type (RW) Description
3501 1 R Control Label (Pass From Config)
Config Example

All state configs must be part of a dictionary called meterControlBlocks.

"meterControlBlocks" : {
    "Meter1" : {
        "enabled" : true,
        "label" : "State01",
        "meterInstanceTag" : "Meter1",
        "index" : 1,
        "bridgeIndex" : 1,
        "subscribeOnStart" : false
    }
}

In the provided example config object, given a base object key of dsp-1, this control would have a standalone key of dsp-1--Meter1.

Config Notes

enabled - enables the control to be subscribed and controlled. label - Passed directly across the eisc as the Label value. meterInstanceTag - Instance tag of the meter control index - Index of the control point. bridgeIndex - The index of the control on a Legacy object subscribeOnStart - Optional, default false. true streams the meter from session start without a subscribe join or Subscribe() call, for standalone programs. The subscribe join and UnSubscribe() still stop it.


Crosspoint State Control

Provides a control point for a single crosspoint on a MatrixMixer.

Within the Legacy object, each crosspoint takes a block of 3 joins: join number = Join Map Number + (bridgeIndex − 1) × 3. bridgeIndex counts from 1; a crosspoint with bridgeIndex 0 is logged and not linked.

Within the Standalone object, the joins are numbered differently from the Legacy object (On, Off, Toggle), as listed below.

This control implements Essentials interface IKeyed

Digitals
Legacy Join Standalone Join Type (RW) Description
2001 3 RW Crosspoint Toggle (feedback: crosspoint on)
2002 1 RW Crosspoint On (feedback: crosspoint on)
2003 2 RW Crosspoint Off (feedback: crosspoint off)
Analogs

None

Serials
Legacy Join Standalone Join Type (RW) Description
2001 1 R Control Label (Pass From Config)
Config Example

All state configs must be part of a dictionary called crosspointStateControlBlocks.

"crosspointStateControlBlocks" : {
    "Crosspoint1" : {
        "enabled" : true,
        "label" : "Crosspoint1-2",
        "matrixInstanceTag" : "Meter1",
        "index1" : 1,
        "index2" : 2,
        "bridgeIndex" : 1
    }
}

In the provided example config object, given a base object key of dsp-1, this control would have a standalone key of dsp-1--Crosspoint1.

Config Notes

enabled - enables the control to be subscribed and controlled
label - Passed directly across the eisc as the Label value
index1 - Input of the crosspoint to be controlled
index2 - Output of the crosspoint to be controlled
stateInstanceTag - Instance tag of the meter block
bridgeIndex - The index of the control on a Legacy object


RoomCombiner

Controls Biamp Tesira RoomCombiner objects. Control of LevelOut, MuteOut, and group selection is supported.

MuteOut is not a subscribed control for this block. Polling is simulated on each trigger of the mute, but there is no unsolicited feedback for mute status.

In order to keep the types of joins similar to a standard fader object, the choice was made to not provide direct control for wall states in this component. If direct wall state control is required, utilize a State Control block.

Within the Legacy object, this Join map represents a control that is part of an array of controls. Each join number = Join Map Number + roomCombiner bridgeIndex as defined by the config. Each combiner takes six joins (offset ((bridgeIndex − 1) × 6)); bridgeIndex 1–66 fits before the router joins at 2601, and a higher one is logged and not linked.

Within the Standalone object, this join map represents a single control as defined by the key in the bridge.

This control implements Essentials interfaces IBasicVolumeWithFeedback and IKeyed

Digitals
Legacy Join Standalone Join Type (RW) Description
2206 6 R Channel Visible
2203 5 RW Mute Toggle
2204 3 RW Mute On
2205 4 RW Mute Off
2201 1 W Volume Up
2202 2 W Volume Down
Analogs
Legacy Join Standalone Join Type (RW) Description
2201 1 RW Volume Level
2202 2 R Icon (0 - Level, 1 - Mic)
2204 3 RW Set/Get the Combine Group Number for Room Combination
2203 4 R Permissions (Pass From Config)
Serials
Legacy Join Standalone Join Type (RW) Description
2201 1 R Control Label (Pass From Config)
Config Example

All RoomCombiner configs must be part of a dictionary called roomCombinerControlBlocks.

"roomCombinerControlBlocks": {
    "Room01": {
        "enabled": true,
        "label": "Room 1",
        "isMic": false,
        "roomIndex" : 1,
        "roomCombinerInstanceTag": "RoomCombiner1",
        "unmuteOnVolChange" : true,
        "incrementAmount" : "2.0",
        "permissions" : 0,
        "bridgeIndex" : 1
    }
Config Notes

enabled - enables the control to be subscribed and controlled. label - Passed directly across the eisc as the Label value. isMic - drives the icon feedback. roomIndex - Index of the room on the combiner block. roomCombinerInstanceTag - Instance tag of the room combiner control. unmuteOnVolChange - if true, will unmute a muted control when the level increases. incrementAmount - the value in decimals by which a mute increment or decrement command will manipulate the level. permissions - Passed directly across the eisc as the Permissions value. bridgeIndex - The index of the control on a Legacy object

In the provided example config object, given a base object key of dsp-1, this control would have a standalone key of dsp-1--Room01.


Tesira Expanders

Provides status updates for tesira expander devices related to health and device properties

Tesira Expander block is not supported in the Legacy bridge API. In order to utilize this control, one must directly bridge the control using the key <dspKey>--Expanders

Within the Standalone object, this join map represents each element in a list of Expander Devices

Digitals
Legacy Join Standalone Join Type (RW) Description
N/A 1 R Device Online
Analogs
Legacy Join Standalone Join Type (RW) Description
N/A N/A N/A N/A
Serials
Legacy Join Standalone Join Type (RW) Description
N/A 1 R Expander Hostname
N/A 2 R Expander Serial Number
N/A 3 R Expander Firmware
N/A 4 R Expaner MAC Address
Config Example

All Tesira Expander config objects must be part of a dictionary called tesiraExpanderBlocks.

"tesiraExpanderBlocks": {
    "Expander01": {
        "hostname" : "MIC-01"
        "index" : 1
    },
    "Expander02": {
        "hostname" : "AMP-01"
        "index" : 2
    }
}
Config Notes

hostname - The hostname of the expander to be tracked. This value must match the configured expander index - The index within the bridged control where this device ins mapped. The joinmap of a device is equal to the join multipled by the index

In the provided example config object, given a base object key of dsp-1, this control would have a standalone key of dsp-1--Expanders.


Full Example Essentials Device Config

This config will create an internal loopback EISC on IPID D1 for a ssh-controlled tesira.

{
    "system": {},
    "system_url": "http://portal-QA.devcloud.pepperdash.com/templates/0f50640b-bc89-42d5-998f-81d137d3fc98#/template_summary",
    "template": {
        "devices": [
            {
                "key": "processor",
                "uid": 0,
                "type": "rmc3",
                "name": "RMC3",
                "group": "processor",
                "supportedConfigModes": [
                    "compliance",
                    "essentials"
                ],
                "supportedSystemTypes": [
                    "hudType",
                    "presType",
                    "vtcType",
                    "custom"
                ],
                "supportsCompliance": true,
                "properties": {}
            },
            {
                "key": "TesiraDsp-1",
                "name": "TesiraDspTesting",
                "type": "tesiraDsp",
                "group": "dsp",
                "properties": {
                    "control": {
                        "endOfLineString": "\n",
                        "deviceReadyResponsePattern": "",
                        "method": "ssh",
                        "tcpSshProperties": {
                            "address": "10.11.50.191",
                            "port": 22,
                            "autoReconnect": true,
                            "AutoReconnectIntervalMs": 10000,
                            "username": "default",
                            "password": "default"
                        }
                    },
                    "faderControlBlocks": {
                        "Fader1": {
                            "enabled": true,
                            "isMic": false,
                            "hasLevel": true,
                            "hasMute": true,
                            "index1" : 1,
                            "index2" : 0,
                            "label": "Room",
                            "levelInstanceTag": "ROOMVOL",
                            "muteInstanceTag": "ROOMVOL",
                            "unmuteOnVolChange" : true,
                            "incrementAmount" : "2.0",
                            "permissions" : 0,
                            "bridgeIndex" : 1

                        },
                        "Fader2": {
                            "enabled": true,
                            "isMic": false,
                            "hasLevel": true,
                            "hasMute": true,
                            "index1" : 1,
                            "index2" : 0,
                            "label": "VTC",
                            "levelInstanceTag": "VTCRXVOL",
                            "muteInstanceTag": "VTCRXVOL",
                            "unmuteOnVolChange" : true,
                            "incrementAmount" : "2.0"
                            "permissions" : 1,
                            "bridgeIndex" : 2
                        },
                        "Fader3": {
                            "enabled": true,
                            "isMic": false,
                            "hasLevel": true,
                            "hasMute": true,
                            "index1" : 1,
                            "index2" : 0,
                            "label": "ATC",
                            "levelInstanceTag": "ATCRXVOL",
                            "muteInstanceTag": "ATCRXVOL",
                            "unmuteOnVolChange" : true,
                            "incrementAmount" : "2.0"
                            "permissions" : 2,
                            "bridgeIndex" : 3
                        },
                        "Fader4": {
                            "enabled": true,
                            "isMic": false,
                            "hasLevel": true,
                            "hasMute": true,
                            "index1" : 1,
                            "index2" : 0,
                            "label": "PGM",
                            "levelInstanceTag": "PGMVOL",
                            "muteInstanceTag": "PGMVOL",
                            "unmuteOnVolChange" : true,
                            "incrementAmount" : "2.0"
                            "permissions" : 0,
                            "bridgeIndex" : 4
                        }
                    },
                    "dialerControlBlocks" : {
                        "Dialer1" : {
                            "enabled" : true,
                            "label" : "Dialer 1",
                            "isVoip" : true,
                            "dialerInstanceTag" : "Dialer1",
                            "controlStatusInstanceTag" : "VoIPControlStatus1",
                            "index" : 1,
                            "callAppearance" : 1,
                            "clearOnHangup" : true,
                            "appendDtmf" : false
                            "bridgeIndex" : 1
                        }
                    },
                    "stateControlBlocks" : {
                        "State1" : {
                            "enabled" : true,
                            "label" : "State01",
                            "stateInstanceTag" : "LogicState1",
                            "index" : 1,
                            "bridgeIndex" : 1
                        },
                        "State2" : {
                            "enabled" : true,
                            "label" : "State02",
                            "stateInstanceTag" : "LogicState1",
                            "index" : 2,
                            "bridgeIndex" : 2
                        },
                        "State3" : {
                            "enabled" : true,
                            "label" : "State02",
                            "stateInstanceTag" : "LogicState1",
                            "index" : 3,
                            "bridgeIndex" : 3
                        },
                        "State4" : {
                            "enabled" : true,
                            "label" : "State02",
                            "stateInstanceTag" : "LogicState1",
                            "index" : 4
                            "bridgeIndex" : 4
                        }
                    },
                    "switcherControlBlocks" : {
                        "switcherControl1" : {
                            "enabled" : true,
                            "label" : "switcher01",
                            "switcherInstanceTag" : "SourceSelector1",
                            "index1" : 1,
                            "bridgeIndex" : 1,
                            "switcherInputs" : {
                                "1" : {"label": "Input1" },
                                "2" : {"label": "Input2" },
                            },
                            "switcherOutputs" : {
                                "1" : {"label": "Output1" },
                                "2" : {"label": "Output2" },
                            }
                        }
                    },
                    "crosspointStateControlBlocks" : {
                        "Crosspoint1" : {
                            "enabled" : true,
                            "label" : "Crosspoint1-2",
                            "matrixInstanceTag" : "Meter1",
                            "index1" : 1,
                            "index2" : 2,
                            "bridgeIndex" : 1
                        }
                    },
                    "meterControlBlocks" : {
                        "Meter1" : {
                            "enabled" : true,
                            "label" : "State01",
                            "meterInstanceTag" : "Meter1",
                            "index" : 1,
                            "bridgeIndex" : 1
                        }
                    },
                    "roomCombinerControlBlocks": {
                        "Room01": {
                            "enabled": true,
                            "label": "Room 1",
                            "isMic": false,
                            "roomIndex" : 1,
                            "roomCombinerInstanceTag": "RoomCombiner1",
                            "unmuteOnVolChange" : true,
                            "incrementAmount" : "2.0",
                            "permissions" : 0,
                            "bridgeIndex" : 1
                        }
                     },
                    "presets" : {
                        "1": {
                            "label" : "Default",
                            "preset" : "Default Levels"
                            "presetIndex" : 1  
                        },
                        "2" : {
                            "label" : "High",
                            "Preset" : "Noise Reduction High"
                            "presetIndex" : 2
                        }
                    },
                    "tesiraExpanderBlocks": {
                        "Expander01": {
                            "hostname" : "MIC-01"
                            "index" : 1
                        },
                        "Expander02": {
                            "hostname" : "AMP-01"
                            "index" : 2
                        }
                    }
                }
            },
            {
                "key": "eisc-Dsp",
                "uid": 4,
                "name": "Bridge Dsp",
                "group": "api",
                "type": "eiscApiAdvanced",
                "properties": {
                    "control": {
                        "tcpSshProperties": {
                            "address": "127.0.0.2",
                            "port": 0
                        },
                        "ipid": "D1",
                        "method": "ipidTcp"
                    },
                    "devices": [
                        {
                            "deviceKey": "TesiraDsp-1",
                            "joinStart": 1
                        }
                    ]
                }
            }
        ],
        "info": {
            "comment": "",
            "lastModifiedDate": "2017-03-06T23:14:40.290Z",
            "lastUid": 12,
            "processorType": "Rmc3",
            "requiredControlSofwareVersion": "",
            "systemType": "MPR"
        },
        "rooms": [],
        "tieLines": []
    }
}

RoadMap

A Method by which we can continue even with "bad" instance tags in the config. Currently, this causes everything to fail upon subscription.

Product Compatible and additional computed target framework versions.
.NET net8.0 is compatible.  net8.0-android was computed.  net8.0-browser was computed.  net8.0-ios was computed.  net8.0-maccatalyst was computed.  net8.0-macos was computed.  net8.0-tvos was computed.  net8.0-windows was computed.  net9.0 was computed.  net9.0-android was computed.  net9.0-browser was computed.  net9.0-ios was computed.  net9.0-maccatalyst was computed.  net9.0-macos was computed.  net9.0-tvos was computed.  net9.0-windows was computed.  net10.0 was computed.  net10.0-android was computed.  net10.0-browser was computed.  net10.0-ios was computed.  net10.0-maccatalyst was computed.  net10.0-macos was computed.  net10.0-tvos was computed.  net10.0-windows was computed. 
Compatible target framework(s)
Included target framework(s) (in package)
Learn more about Target Frameworks and .NET Standard.

NuGet packages

This package is not used by any NuGet packages.

GitHub repositories

This package is not used by any popular GitHub repositories.

Version Downloads Last Updated
4.6.1 72 11/18/2026
4.6.0 63 11/16/2026
4.6.0-feat-mock-selector-ro... 63 11/16/2026
4.6.0-feat-mock-selector-ro... 70 11/16/2026
4.5.2-fix-watchdog-quaranti... 61 11/10/2026
4.5.2-fix-watchdog-quaranti... 66 11/10/2026
4.5.2-fix-watchdog-quaranti... 65 11/10/2026
4.5.2-fix-watchdog-quaranti... 69 11/10/2026
4.0.0-integration-v3-improv... 66 10/30/2026
4.0.0-integration-v3-improv... 60 10/29/2026
4.0.0-integration-v3-improv... 62 10/29/2026
4.0.0-fix-neil-review-183.2 57 10/30/2026
4.0.0-fix-neil-review-183.1 63 10/30/2026
4.0.0-fix-integration-revie... 59 10/29/2026
4.0.0-fix-integration-revie... 63 10/29/2026
4.0.0-feature-add-essential... 63 10/30/2026
4.0.0-docs-upgrading-to-v4.1 65 10/30/2026
3.8.3-port-v2-phase1.3 63 10/30/2026
3.8.3-port-v2-phase1.2 66 10/30/2026
3.8.3-port-v2-phase1.1 71 10/30/2026
Loading failed