nanoFramework.Iot.Device.Tsl256x 1.2.869

Prefix Reserved
dotnet add package nanoFramework.Iot.Device.Tsl256x --version 1.2.869
                    
NuGet\Install-Package nanoFramework.Iot.Device.Tsl256x -Version 1.2.869
                    
This command is intended to be used within the Package Manager Console in Visual Studio, as it uses the NuGet module's version of Install-Package.
<PackageReference Include="nanoFramework.Iot.Device.Tsl256x" Version="1.2.869" />
                    
For projects that support PackageReference, copy this XML node into the project file to reference the package.
<PackageVersion Include="nanoFramework.Iot.Device.Tsl256x" Version="1.2.869" />
                    
Directory.Packages.props
<PackageReference Include="nanoFramework.Iot.Device.Tsl256x" />
                    
Project file
For projects that support Central Package Management (CPM), copy this XML node into the solution Directory.Packages.props file to version the package.
paket add nanoFramework.Iot.Device.Tsl256x --version 1.2.869
                    
#r "nuget: nanoFramework.Iot.Device.Tsl256x, 1.2.869"
                    
#r directive can be used in F# Interactive and Polyglot Notebooks. Copy this into the interactive tool or source code of the script to reference the package.
#addin nuget:?package=nanoFramework.Iot.Device.Tsl256x&version=1.2.869
                    
Install as a Cake Addin
#tool nuget:?package=nanoFramework.Iot.Device.Tsl256x&version=1.2.869
                    
Install as a Cake Tool

TSL256x/TSL2560/TSL2561 - Illuminance sensor

TSL2560 and TSL2561 are illuminance sensor. They are light-to-digital converters that transform light intensity to a digital signal output capable of direct I2C (TSL2561) or SMBus (TSL2560) interface. Each device combines one broadband photodiode (visible plus infrared) and one infrared-responding photodiode on a single CMOS integrated circuit capable of providing a near-photopic response over an effective 20-bit dynamic range (16-bit resolution).

Two integrating ADCs convert the photodiode currents to a digital output that represents the irradiance measured on each channel. This digital output can be input to a microprocessor where illuminance (ambient light level) in lux is derived using an empirical formula to approximate the human eye response.

The TSL2560 device permits an SMB-Alert style interrupt, and the TSL2561 device supports a traditional level style interrupt that remains asserted until the firmware clears it.

Documentation

Board

image

Usage

Basic usage

TSL2560 and TSL2561 are designed to have an integration time and a gain for measuring the 2 ADC. The defaults are 402 milliseconds and a normal gain of x1.

The basic usage is the following:

I2cDevice i2cDevice = I2cDevice.Create(new I2cConnectionSettings(1, Tsl256x.DefaultI2cAddress));
Tsl256x tsl256X = new(i2cDevice, PackageType.Other);
tsl256X.IntegrationTime = IntegrationTime.Integration402Milliseconds;
tsl256X.Gain = Gain.Normal;
var lux = tsl256X.MeasureAndGetIlluminance();
Console.WriteLine($"Illuminance is {lux.Lux} Lux");

notes:

  • Be aware, there are 2 types of packaging the CS and the Others T, FN and CL. Refer to the documentation to understand which package you have on the board. This is an argument when creating the sensor as the calculation for the illuminance is different.
  • There are 3 different possible I2C addresses for this device depending on how the address pin is setup:
    • DefaultI2cAddress = 0x39: When address pin is to the ground
    • SecondI2cAddress = 0x29: When address pin is floating
    • ThirdI2cAddress = 0x49: When address pin is to VDD

Check the version

You can determine if you have a TSL2560 or TSL2561 version:

var ver = tsl256X.Version;
string msg = ver.Major & 0x01 == 0x01 ? $"This is a TSL2561, version {ver}" : $"This is a TSL2560, version {ver}";
Console.WriteLine(msg);

Using interruptions

You can set interruptions, you have different possible ones you can set thru the InterruptLevel:

  • OutputDisabled: will disable the interrupt
  • LevelInterrupt: will use the permanent interrupt you'll setup, see right after
  • SmbAlertCompliant: will send an alert on the SMB bus (version TSL2560 only) on address 0b0000_1100
  • TestMode: will generate an interruption for test purpose

The InterruptPersistence will allow you to select a specific timing for the interrupt:

  • EveryAdc: each time you have a measurement
  • AnyValueOutsideThreshold: any time a value will be outside of the setup threshold
  • OutOfRangeXXIntegrationTimePeriods: where XX is from 2 to 15, will interrupt only if the value remains outside more than XX times

The following example shows how to setup a basic interruption using test mode:

Console.WriteLine("Set interruption to test. Read the interrupt pin");
GpioController controller = new();
controller.OpenPin(PinInterrupt, PinMode.Input);
tsl256X.InterruptControl = InterruptControl.TestMode;
tsl256X.Enabled = true;
while (controller.Read(PinInterrupt) == PinValue.High)
{
    Thread.Sleep(1);
}

Console.WriteLine($"Interrupt detected, read the value to clear the interrupt");
tsl256X.GetRawChannels(out ushort ch0, out ushort ch1);

You can setup interruptions on thresholds as well. You first need to setup a threshold and then the type of interruptions.

// Adjust those values with a previous measurement to understand the conditions, find a level where then you can
// hide the sensor with your arm and make it going under the minimum level or vice versa with a lamp
tsl256X.SetThreshold(0x0000, 0x00FF);
tsl256X.InterruptPersistence = InterruptPersistence.OutOfRange06IntegrationTimePeriods;
tsl256X.InterruptControl = InterruptControl.LevelInterrupt;
tsl256X.Power = true;
while (controller.Read(PinInterrupt) == PinValue.High)
{
    Thread.Sleep(1);
}

Console.WriteLine($"Interrupt detected, read the value to clear the interrupt");
tsl256X.GetRawChannels(out ch0, out ch1);
Console.WriteLine($"Raw data channel 0 {ch0}, channel 1 {ch1}");

Manual integration

You can set a manual integration as well. Be aware that you won't be able to easily calculate an illuminance equivalent. You need to use the manual integration functions offered:

Console.WriteLine("This will use a manual integration for 2 seconds");
tsl256X.StartManualIntegration();
Thread.Sleep(2000);
tsl256X.StopManualIntegration();
tsl256X.GetRawChannels(out ch0, out ch1);
Console.WriteLine($"Raw data channel 0 {ch0}, channel 1 {ch1}");
Product Compatible and additional computed target framework versions.
.NET Framework net is compatible. 
Compatible target framework(s)
Included target framework(s) (in package)
Learn more about Target Frameworks and .NET Standard.

NuGet packages

This package is not used by any NuGet packages.

GitHub repositories

This package is not used by any popular GitHub repositories.

Version Downloads Last Updated
1.2.869 189 4/2/2025
1.2.864 177 4/2/2025
1.2.852 201 3/11/2025
1.2.846 205 3/10/2025
1.2.822 126 2/26/2025
1.2.775 134 2/4/2025
1.2.772 124 2/4/2025
1.2.755 137 1/31/2025
1.2.743 129 1/20/2025
1.2.737 110 1/13/2025
1.2.718 119 12/30/2024
1.2.704 119 12/18/2024
1.2.696 117 12/16/2024
1.2.673 124 10/23/2024
1.2.656 134 10/3/2024
1.2.639 163 9/6/2024
1.2.631 146 8/28/2024
1.2.613 150 8/9/2024
1.2.601 126 7/26/2024
1.2.590 130 7/17/2024
1.2.573 152 6/19/2024
1.2.570 150 6/14/2024
1.2.536 151 4/15/2024
1.2.534 150 4/13/2024
1.2.514 151 3/22/2024
1.2.494 158 2/28/2024
1.2.462 229 1/5/2024
1.2.458 177 12/20/2023
1.2.436 191 11/10/2023
1.2.416 128 11/8/2023
1.2.403 171 10/6/2023
1.2.396 170 9/27/2023
1.2.384 173 9/6/2023
1.2.378 187 8/16/2023
1.2.369 193 8/2/2023
1.2.363 186 7/28/2023
1.2.357 199 7/19/2023
1.2.354 210 7/14/2023
1.2.345 188 6/21/2023
1.2.341 196 6/14/2023
1.2.337 213 6/7/2023
1.2.335 210 6/2/2023
1.2.329 206 5/26/2023
1.2.316 211 5/16/2023
1.2.313 215 5/12/2023
1.2.302 217 5/10/2023
1.2.297 198 5/3/2023
1.2.273 300 3/17/2023
1.2.267 303 3/10/2023
1.2.263 285 3/8/2023
1.2.259 313 2/27/2023
1.2.256 323 2/24/2023
1.2.253 320 2/22/2023
1.2.222 367 1/9/2023
1.2.217 354 1/6/2023
1.2.212 354 1/5/2023
1.2.208 381 1/3/2023
1.2.203 374 12/28/2022
1.2.159 434 11/14/2022
1.2.153 419 11/5/2022
1.2.141 459 10/25/2022
1.2.128 458 10/22/2022
1.2.125 462 10/12/2022
1.2.87 564 9/15/2022
1.2.63 470 9/3/2022
1.2.47 493 8/15/2022
1.2.40 485 8/6/2022
1.2.38 498 8/5/2022
1.2.28 473 8/1/2022
1.2.13 499 7/24/2022
1.2.10 508 7/23/2022
1.1.142.3202 526 7/7/2022
1.1.133.52556 506 6/30/2022
1.1.121.35854 514 6/26/2022
1.1.118.19693 513 6/24/2022
1.1.116.8772 500 6/24/2022
1.1.102.51394 484 6/15/2022
1.1.99.36719 486 6/14/2022
1.1.97.17326 506 6/13/2022
1.1.92.53000 500 6/8/2022
1.1.72.29765 503 5/31/2022
1.1.61.27737 517 5/25/2022
1.1.58.10097 511 5/23/2022
1.1.54.28879 500 5/23/2022
1.1.40 534 5/5/2022
1.1.3 519 4/15/2022
1.1.1 528 4/14/2022
1.0.300 529 4/3/2022
1.0.288-preview.113 176 3/25/2022
1.0.288-preview.107 167 3/24/2022
1.0.288-preview.104 164 3/22/2022
1.0.288-preview.103 167 3/21/2022
1.0.288-preview.99 173 3/18/2022
1.0.288-preview.94 182 3/15/2022
1.0.288-preview.77 185 2/27/2022
1.0.288-preview.75 167 2/26/2022
1.0.288-preview.63 179 2/16/2022
1.0.288-preview.61 180 2/12/2022
1.0.288-preview.58 180 2/10/2022
1.0.288-preview.53 184 2/9/2022
1.0.288-preview.48 197 2/4/2022
1.0.288-preview.41 191 1/31/2022
1.0.288-preview.22 180 1/27/2022
1.0.288-preview.20 192 1/27/2022
1.0.288-preview.18 200 1/27/2022
1.0.272 560 1/10/2022
1.0.260 389 12/10/2021
1.0.259 392 12/9/2021
1.0.258 375 12/7/2021
1.0.231 400 10/27/2021